Under your metal roofing you need roofing underlayment to catch the dripping condensation.
Skip sheathing metal roof.
The entire roof deck is relatively uniform where you can step on any part of it without slipping through spaces.
Installing wood stripping under a tin roof.
The underlayment is very important.
Tin roofing also known as metal roofing is considered more durable than composition or wood shingles.
Exposed or hidden fasteners.
And you b don tneed to sheath the roof the difference in price between a 4x8 sheet of osb or ply and 8 pieces of 1x4x8 for exmple is big.
I am having a stone coated metal roof installed on my house that has a tile roof.
Board and batten pan and ridge panels.
As well as all valley s.
Grace ice and water shield or titanium udl50 is recommended along the eave up to 3 0 beyond the inside of the exterior wall.
Many metal roofing dealers specify minimum of 7 16 sheathing.
First of all thanks for selecting a metal roof.
Panel or tile system.
On metal frame building and the like you will likely see structural metal roofing installed on purlins that is what those 1x4 are purlins and those metal roofing panels are rated for that type of installation.
Most formed metal roofing the type that imitates wood slate or clay comes with a built in thermal break that insulates against heat passing to the roof deck below.
Shake and shingle panels.
Lets pretend the roof design details are conventional and so the roof deck sheathing will be 5 8 to 3 4.
Skip sheeting or spaced sheathing is just as it sounds.
And unlike asphalt slate or clay roofs that hold onto solar heat after the sun goes down metal quickly releases its heat back into the atmosphere.
Under the tile there is no felt paper or solid sheathing.
Sheathing with gaps between.
The time saved in humping edless 4x8 sheets up onto the roof nailing them off and creating staging areas to work from is b huge as you install the strapping purlins at 24 oc you are creating a.
Next purlins parallel to the eaves and then roofing.
The roofing is manufactured in panels that.
Most you see on homes and many commercial building is non structural metal roofing and needs to be on solid sheathing.
You ll want to use both longer sheathing nails and longer roofing nails.
The tile roof system leaks like a seive the metal roof contractors are proposing laying the 30 felt paper directly over the skip sheathing.
On top of your insulation you need an air barrier.
There is only skip sheathing present.
Design depends on type of metal roof.
Installing over skip sheathing is fine.
Osb or plywood over skip sheathing makes for a much stiffer roof deck resists problems with expansion better and obviously doesn t require all the hassle of removing it.
Traditionally skip sheathing consists of 1 inch by 4 inch boards nailed to the rafters with gaps between the boards.