If different from above street.
Smacna duct leakage test form.
Contains updates to the expected leakage rates for ductwork constructed to the smacna hvac duct construction standards metal flexible duct leakage test procedures recommendations on use of leakage testing types.
Duct leakage class consult the hvac air duct leakage test manual and select appropriate allowable leakage.
Inches wg download the iphone app here.
Resource hvac air duct leakage.
This american national standard ansi smacna 016 2012 covers revised leakage criteria and builds on the proven methods for testing ductwork for air leaks from the first edition.
When the designer has only required leakage tests to be conducted in accordance with the smacna hvac air duct leakage test manual for verification that the leakage classifications in table 1 have been met and has given no other criteria and scope he is deemed to have not fulfilled the responsibilities outlined in section 2 1 for providing a.
Hvac duct air leakage oct 10 2019 in a recent article which was published in rses journal smacna s senior project manager pat brooks pe discusses the history of duct air leak testing and describes proper techniques and practical applications when leak testing is performed in accordance with smacna standards.
Example blank form duct leakage test form customer information.
Us duct leakage testing ri trequirements smacna duct class 1 2 inwg 3 inwg 4 6 10 inwg seal class cb a sli t transverse joints seams sealing applicable ransverse joints only asvese joints and seams jo s sea s and all wall penetrations leakage class c l cfm leakage per 100 ft2 1 in h 2 o rectangular metal 24 12 6 round.
This article discusses the history of duct air leak testing and describes proper techniques and practical application when leak testing is performed in accordance with the sheet metal and air conditioning contractors national association smacna standards.
Figure 5 1l from the 2012 smacna hvac air duct leakage test manual shows the allowable leakage as a function of duct leakage classification and static pressure in the duct.
Leakage class can be calculated using equation 3 but needs to be specified if duct air leakage tests are required.
Duct liner metal nosing shall be used on leading edges of each piece of lined duct when the velocity exceeds 4000 fpm.
Hvac air duct leakage this article discusses the history of duct air leak testing and describes proper techniques and practical application when leak testing is performed in accordance with the sheet metal and air conditioning contractors national association smacna standards.